Ideal instinct2 24 boiler
I have an ideal instinct2 24 combi boiler. I have the central heating AND hot water connected to the central heating side of the boiler. I have a unvented water tank. The heating is controlled by an EPH wireless thermostat and motorised valve. The hot water is controlled by a Honeywell ST9100 timer and motorised valve.…
-
Live and Neutral termination?
Can I terminate the live and neutral in parking terminals on the thermostat?
-
Valiant eBus with relay output
Hey there, Will try to explain my set up and hopefully the problem. I have a vaillant ecotec boiler and have been using the tado thermostat wirelessly and extension kit with ebus to the boiler. Works perfectly!!! I would not like to add a second thermostat - but I need this one to control my underfloor heating in a…
-
Tado compatibility with Global Energy Systems ASHP's (Specifically Thurso 10Kw model)?
Hello all, I see there are lots of questions regarding compatibility with specific ASHPs, but none relate to my particular brand / model. Does anybody have any experience with this combination of pump and controller? I believe I'll need a 'wired smart controller' ? My existing GES controller has to remain as it does not…
-
Smart TRV Questions
Hi, Apologies if any of my questions have been answered, but I was unsure how to find them and what terms to use! I'm about to get the VR3+ starter kit installed, and am looking to get smart TRV's added to further increase my saving capablities. My plan is to get one in each bedroom and one in the living room. If I set the…
-
Do I change my manual rad valve to a srv in the same room as my tado thermostat
I'm a little unsure what to do in my hallway, currently I have a wireless thermostat and one radiator with a manual rad valve. I am going to fit my tado wireless thermostat there, however I am unsure if it is better to keep the manual valve on the radiator, or change it to a tado srv.
-
No response from customer support
I have been waiting 193 hours for an answer to a simple question. I'm asking for my money back. Can anyone recommend a better manufacturer? Tado seem like a very difficult company to communicate with.
-
New boiler fitted . Tado not working
Had a new vailliant ecofit pure 415 installed and setting tado to ebus works boiler but not the hot water and heating valves from the extension kit. Resetting unit to relay control allows extension module to control relays but no control over boiler via ebus. Anyone any ideas what I am missing.
-
Tado received needing to be reset daily
Last weekend I removed a room thermostat and knocked off the master fuse. Since then, I have to daily press the heat button on the tado receiver attached to my boiler. I've tried resetting the bridge but no luck. Can anyone please help?
-
Heat request with gas boiler, relay
Hello, I have a gas boiler (ferroli nem elite 60) and my tado tried to use heat request functionality. The boiler starts only on level 3 ( and its’s ok, because it’s just a relay). How can I turn off in tado app the heat request support and only use just 0 & 3 (on/off)? thanks!
-
Smart radiator thermostat keeps on recalibrating and not updating
Hi there, I have installed five radiator thermostats and I have a problem with one of them. The thermostat is not updating and when I connected it to the radiator it calibrated just fine but it started to recalibrate every five minutes. I have tried to pair it again, reset it, changed batteries ut in two days they where…
-
Installation help
I have a Worcester Bosh Greenstar 30i ERP boiler fitted with a Drayton LP10RF programmer. How do I wire in my extension kit? All I need is to control the heating wirelessly. Pics attached of the existing wiring. I have contacted Tado Support several times now with pictures asking for help but have no response yet and I'm…
-
A little more info about the upcoming(?) new network bridge please?
Being one of the many that have range issues, I've been reading through the posts on the topic & have seen a couple of mentions from @Rob about (I think) a new bridge in development that will allow multiple home setups, and in a post it was suggested that this would let you have more than one in the same house. I would…
-
Instructions mention removing bridge - I don’t see one?
Hey folks wondering if folks could point me in the right direction. The app installation mentions removing a bridge, but I don’t see one on my setup. So throwing out a question so I don’t get it wrong.
-
Remote access
Should I be able to control my heating while away from home? Just asking because I expected to and can't do so.
-
Reoccurring daily Temp spike
Every day at approx 15:20 I am getting my boiler come on, even though the house is above the trigger temp. I look at the app and it shows black and off during this time. It doesn't show any request for heat though even as the boiler is firing! I wish I could post screen shots, but there's no option to...
-
App says Wireless Receiver isn't connected
The app/website says my wireless receiver is disconnected. I checked the lights on it and I have steady white lights for the power and wireless. The bridge has all three lights on and steady. Held the main button down for 10 seconds to restart the wireless receiver. Still didn't show as connected in the app. Triggered…
-
Old thermostats are cooling so I Tado isn't compatible? (according to Tado)
So I want to upgrade my thermostats to work with my combi boiler. I have emailed support and got a weird answer I don't understand. (I have two boilers in a house so was going to add two tado installs which is a whole other can of worms I know!) Anyway downstairs I have a combi Boiler an Ideal logic combi c24ie and a hagar…
-
Factory reset
Can I do a complete factory reset as I have an error light flashing but no error on the system?
-
Do I still need the Alpha Easy-stat connected?
I’ve just installed the Tado starter kit (wireless smart thermostat v3+), we have an Alpha Eco2 Plus boiler, which has a “Easy-stat wireless programmable room thermostat”… and it’s not clear to me if this should be still connected/ used. There is no wired thermostat. As far as I can tell the way to set the boiler to…
-
A Bridge Too Far?
I got one bridge with my starter TVR kit. If I get a room stat I'll get another bridge. Do I have to use both? Do they each serve a different function? If I only use the first one, is it possible to buy a room stat without a bridge as the only ones I see for sale all have a bridge?
-
Radiators only heating when hall radiator is on
i have searched this topic and it appears it has been discussed before but I am still confused how to fix it. We have the extension kit (in kitchen) a wired thermostat in the hall and individual valves on each radiator eg in living room, bedrooms etc. currently the rooms will not heat up unless the hall radiator is on…
-
New To Tado - TRV and wirless sensor
I have a couple of questions please. I have a Glow Worm boiler which is operated via a wired box by the boiler and a wireless room thermostat which controls the room/house temperature. When ordering which system do I specify, the boiler or thermostat/receiver make? Do I need to replace ALL existing trvs with the tado smart…
-
How to I link my tado system to Alexa?
How do I link my tado system to alexa?
-
Inwieweit wird der Verbrauch pro Raum in der App korrekt angezeigt?
Wir haben die Daten der App mit den Zahlen auf den Heizkostenverteilern überprüft. Diese stimme bei weitem nicht überein. Beispiel: Kinderzimmer: Heizkostenverteiler: 1300 vs. Tado: 556. Wie kann das sein? Wieso zeigt tado einen viel niedrigeren Wert? Ich hoffe, dass mir jemand bei der Beantwortung der Fragen weiterhelfen…
-
Control all rooms
Hello, New to this TADO, but its exciting.. 😉 Question: Isnt it possible to control ALL rooms at once instead of controlling them individually?
-
Boiler no longer working
Hi, I just installed my Room thermostat today and all worked fine for an hour however the boiler is no longer working at all. It’s a Baxi combo boiler and replaced an old 3 wire sienna room thermostat. Help. What can I do to troubleshoot this please?
-
What is timer for at bottom of individual rooms?
There's a slider which you can adjust timer for individual rooms, what us it for?
-
Why are the radiators not coming on?
So, I've tried installing the Tado receiver as per the instructions they gave me. All lights etc are on as they should be. It appears to talk to the boiler, and I can hear it firing up, but the radiators never seem to come on. Anyone else had this issue? Boiler is a Worchester CDi Greenstar
-
Does tado support Opentherm/bus control and zone valve control together?
I have recently moved to a 3 storey new build and the existing setup has 2 thermostats (On the top and bottom floors) connected to 2 zone valves, the zone valves are then connected to the boiler (which supports Opentherm) on a common connection. I'd like to replace this with a Tado system that will connect to the boiler…