Connecting wireless controller
I have an alpha boiler etec plus 38. Which connections do I connect to the controller?
-
Opentherm UK
I have recently installed my Tado Starter Kit and TRVs and am delighted with my installation. I would now like to go further and have more control. I read from other contributors that Opentherm has been removed from UK Wireless Receivers so a wired Thermostat required. To be clear if I can source a EU Wireless Receiver and…
-
Thermostat question
I have a existing battery Honeywell two wire wall thermostat with a live a switch live. Looking at the instructions these need to be bridged. The Tado thermostat I have is wireless. Any help would be appreciated.
-
Tado Basic Smart SRT v Tado Smart SRT
Are there any differences other than price and the digital display between a Basic SRT and Smart SRT? Is the Smart a newer version?
-
How to wire the replacement of a Honeywell T40 T8762014E
Hi, I am replacing a Honeywell T40 T8762014E with a Tado, however the wiring up is not working. The boiler does not seem to respond to commands and radiators just keep heating up regardless of what I set up the thermostat to do. Can someone advice how I should wire up the 2 cables? there is no indication in the thermostat…
-
OT or weather compensation
Hi if I had the option to choose one of the above which would you recommend to work with Tado? Thanks
-
OpenTherm & Weather Compensation
Got a couple of questions, hoping some can advise. 1: Has anyone fitted weather comp to a combi boiler, when using using Tado with OpenTherm link?, 2: Is there any advantage over and above Tado's internet based weather comp? 3: more importantly wil thery work together or fight each other?
-
New setup with solar
Hi All new here My existing system Vaillant ecoTEC pro 2013 connected to Vaillant VCR 470 programmer. I have had solar fitted this year along with a 200l hot water tank heated via a solar iboost. The hot water tank is also connected to the flow and and return from the boiler via a motorised valve with the idea that when…
-
Zone Controller Help Needed!
Hello, I have today installed two Tado wired Smart thermostats to control my downstairs and upstairs zones, with a wireless receiver to control my Hot water. My out going system is a Danfoss TPOne-M (downstairs zone and HW) and a Danfoss TPOne-B (upstairs zone). Since adding the wireless receiver (and telling it that it…
-
Tado Radiator Thermostat - Smart vs Smart Basic
I've just installed my Starter Kit for heating/hot water - so far, so good. I'm now considering whether to add smart rad valves, and if so, which. Tado seems the obvious choice (tho pretty expensive), but they offer 2 versions, 'Smart V3+' & 'Smart v3+ Basic'. From what I can see on the website…
-
Is it possible to buy/replace a wireless receiver only?
Mine appears to be faulty/broken, I do not need a starter kit though.
-
Suggestion for new valves
Hi, I messed up and miscounted so need to get some new valves for my radiators. Too many have the old style rectangular turning bit rather than a TRV. Does anyone know where to get just that body part in the U.K. Everywhere I look is selling both body and head together, often with the other radiator side too. So much waste…
-
Smart Radiator Valve not calling for heat
Hi, I woke up this morning and my smart trv in the office has stopped calling for heat, for example the room is set to 19 degrees, the actual temperature in the room is 15 degrees but the heating doesn't come on, it's worked up until this morning, only noticed because the office was freezing this morning when I started to…
-
Alexa & tado zones
Is there a way to get an Alexa command to ask what zones are calling for heat? It would be helpful if Alexa were to list what zones are heating currently, Even better if it could tell what the current temp was at the same time
-
Nathaniel - Discussion about "no remote access"
The product... yeah if I knew what I knew now but we are all it the same boat... Bespoke - yeah not so clever...MATTER discuss :) You have just blasted me (black/cyber) with offers - piss off. Your kit works (just) for me but the interface is a dog - sign me up for a monthly sub, £5 a month a wouldn't even blink so long as…
-
Help with wiring
Hi I'm trying to wire the tado for a combi boiler. From the old wiring I have N L 2 and 3 plus a green and yellow and green. For the new wiring where does 2, 3 and the green and yellow and green go to? Thanks
-
Thermostaat reageert niet op ketel
Bedrade thermostaat reageert niet op Remeha Avant 28c ketel, wat nu tr doen?
-
The wired thermostat TADO replaces a Carrefour thermostat in a Ferrol boiler
Boiler: Ferroli DOMIproject F 24 Thermostat: Carrefour type:997651 Only two wires named 1 and 3. In which ports of the TADO thermostat should I insert the cables called 1 and 2 by the carrefour thermostat? Thanks
-
Diematic3
Hello, I understand that my De Dietrich is listed as unsupported, but believe that it has been connected with success several times. Im about to use the basic NO relay connection to pigy back the boilers Auto/Manual switch. But before I do, has anyone used the two resistor technique to trick the S AMB A room temp sensor…
-
Pairing Bridge to room t/stat problem
My first venture into the wonderful world of Tado and not a happy one. Bridge pairing light is flashing and I press the pairing button on the t/stat and get displayed, temperature (seems to be random}, two chain links that eventually link. Tado and then Hi and that's it. App tells me the t/stat is offline. T/stat is more…
-
Preparing Tado for new modulating boiler
A new boiler is on the horizon which will be compatible with OpenTherm. It will be a combi boiler. About a years ago I bought a Wireless Starter Kit V3+ and some Tado TRVs. It's all been working absolutely fine with my old boiler, really happy with it. I now understand that the wireless receiver I have (the three buttoned…
-
RO table for wired t/stat
I'm trying to configure a wired t/stat but the instruction says select the relevant RO number from the table but I don't see the table. Can anyone tell me what the number is for a Worcester Combi boiler or where I can find it. What makes matters worse is that the app has stopped working.
-
Tado heating too much
Hi I have just installed Tado thermostat on all radiators. Especially one of them (the one in the bathroom) keeps on heating way too much. I just found et at +30 degrees Celsius, but it is put to 20 degrees in the app. How do I fix this or is the device broken?
-
Change "hot water control" device?
How can you change the "DEVICES" that are listed under "Settings / Rooms & Devices / HOT WATER CONTROL / Hot Water" in the Tado app? Currently, I have two devices listed: my wireless receiver and one of my wireless temperature sensors. I have two wireless temperature sensors and want to change which controls the hot water…
-
>1 Smart Radiator Thermostats in a room?
How do SRTs function if one has more than one in a room? One sets the room temperature and schedule by room, not by thermostat, but which thermostat reads the room temperature, or do they each work independently based on their individual temperature measurement? Which one is measuring and reporting temperature and humidity?
-
10 Room limitation
Hi, I see this discussion has been closed - any update on increasing the number of rooms above 10? Many thanks
-
Hot water but no heating
Had to change the batteries in the thermostat but although we have hot water the heating hasn't come back on. How do I reconfigure the thermostat to talk to the boiler? Thanks
-
Tado overheats massively
Hey I have an issue with my wired Tado that is connected to our waterbased floor heating from Empur. It’s is massively overheating by sometimes 4-6 degrees. Has anyone else had the issue and knows what to to? Everything is correctly wired.
-
Wireless Temperature sensor doesn't open both smart radiator thermostats included.
After installing a new Wireless Temperature Sensor in the middle of the room between 2 radiators, only one of the radiators is heating up when the Wireless Temperature Sensor is calling for "low level" heat (1 heating wave). If the sensor demands medium or high level of heating (2 or 3 heating waves), I don't experience…
-
TRV call for heat but open with a delay causing my boiler to get in to an error state.
Hi, Since I added more TRV's to my system I am having problems. When all TRV's are closed and one TRV is calling for heat I can see my boiler display working and hot water is being created. I can hear my bypass opening. After a couple of minutes my boiler gives an error(hot water returning is to high -- no radiator can…