How to build a system for a 2 zone + Hot Water Tank
Hi All, Is the Tado system able to do 2 zones + hot water tank? I can't find anything on the website that says it could support this setup. Thanks Fletch
-
Ideal Combi2 Opentherm Error "Room Thermostat Fault (65)" & "Check Room Stat Batteries"
After a very unproductive and frustrating session with tado support I'm hoping I might get some help from the forum. I've a new (2-3 months) ideal combi2 boiler and I've swapped my original extension kit for the EU one to get Opentherm. In testing it all works nicely, and being the summer the boiler has mostly been in…
-
MORCO GB24 BOILER
WILL TADO WORK WITH A MORCO GB24 BOILER
-
How do I change the hot water temperature through Ebus on a Glow-Worm Ultimate 30c
I have a Glow-Worm Ultimate 30c, which is a combi, wired in via Ebus and all is working as it should. The only thing I'm unable to do is to control the hot water temperature. The slider appears in the app, but the change in temperature doesn't reflect on the boiler. With Glow-Worms, if you install one of their own Ebus…
-
Should my pump overrun for any length of time?
Just replaced my old Drayton controller/programmer so I could link the heating to my home automation setup using the Tado V3+ stat. All going great, but I noticed that my pump was still running after the heating had gone off the other day, had been running for at least another 10-15 minutes before I noticed. I turned the…
-
Radiator thermostat won't work
The problem is with the radiator thermostat in our main bedroom. A few weeks ago i started getting messages that the batteries needed changing. I did not get around to it and today we had no heat 1st thing. So I changed the batteries, being very careful to use the new LR6 AA batteries (not rechargeable) becauase I've had…
-
"Your system is not supported" [Climote]
I'm trying to install the Tado Wireless Receiver to be the controller of my boiler (regular / open vent, Ideal SE18 18kw gas boiler). Until ~2 years ago, I had a very standard digital controller to set which hours the boiler would come on, and be able to boost. About 2 years ago, I had the Climote installed by my utility…
-
Q re upgrade from v1 to latest version and radiator thermostats
Hi. I have the very first Tado, v1 which is not compatible with Apple or add ons. I have a very old non-combi boiler which I am in the process of upgrading to combi. Due to compatible issues and a failing battery on the v1, I’m tempted to upgrade to v3 and go with rad thermostats all around so I can can be precise on where…
-
Upstairs / downstairs
I have a Tado thermostat etc. but no Tado radiator thermostats. I want to be able to heat upstairs or heat downstairs or both, so I need some Tado radiator thermostat valves. There are 6 radiators upstairs and 6 radiators downstairs. Looks to me like I need 12 Tado thermostat radiator valves! ££££££ Am I correct? If I just…
-
Wireless receiver is not switching my Vaillant boiler on and off
Hello I have wireless receiver connected via analog 7/8/9 clamps to my Vaillant VU 122/2-5 boiler as per guide but it is not switching the boiler on or off. I have removed the old Vaillant wired thermostat (also connected via 7/8/9 pins) and it is simply not switching the heating on. My Vaillant do not have bus +-…
-
Opentherm connection multi zone
Hi, I have a 2 zone system currently using 2 wired thermostats is relay mode. These thermostats are connected to SRVs in most rooms. Can I connect the 2 wired thermostats to the boiler using the digital opentherm connections. My boiler is opentherm compatible. How will the boiler know which zone the command is from?
-
Replacing Honeywell ST6400C with TADO Wireless Starter kit V3
I have identified the Honeywell wiring as per attached and replaced with the TADO Wireless Receiver using the Y plan wiring instructions. I have assumed CHx = CH NC (5 not wired) & CHo = CH NO as below. (7) HWx = HW NC (4) & HWo = HW NO (6) However the central heating is NOT coming on. Either TEST or Programmed. :-( TADO…
-
How to boost - hot water or, and heating
Depending on the posts I read, I see different answers 1. Can boost directly on the thermostat or receiver - heating and, or hot water 2. Same question as above but the app - is there a separate tile to do this or do you have to delve deep into the app Thanks
-
what tado starter kit to buy
Hi, i have been let down by the chat bots so trying here: I am replacing a system boiler with a Vaillant Ecotec Plus 630 ERP. I have a hotwater storage tank, one zone of wet underfloor , 14 rads in total of which 6 will need to be controlled via smart TRVs. I am unsure what starter kit to buy. the online chat points me to…
-
Floor heating plus radiators
Hi, I have a Vaillant Eco Plus boiler that heats my ground floor with floor heating, and I have one thermostat located in the living area. On the first floor, I have radiators. My issue is that when the ground floor reaches the desired temperature, the boiler shuts down, and this results in the heating stopping in the…
-
TRVs - Battery life
Hi there I recently installed 10 TRVs around the house. Given it hasnt been cold, they havent really been used. However, half of them now need batteries replacing (been there for about 3 months). Is that normal? I cannot believe how quickly they have been depleted. Thanks
-
What do I need?
Hi, can someone please help with what I need for my home? I have searched and searched the Tado website and its very little help and their chatbot is useless! I have a combi boiler with zoned heating (2 zones; upstairs & downstairs). I have the following in my basket; wireless starter kit, an additional wireless thermostat…
-
Honeywell programmer and dry contact
hello, do you know how to wire a programmer to get output as a dry contact ? Meaning without electric current just switch. Here this is a Honeywell programmer st9400. Below the wiring diagram. What I understand is only live current possibility on plots 1,2,3,4. thx !
-
app has no heating control option
ive just intalled my v3 wirless kit. i can control the hot water and heating on the receiver but the app only gives me a hot water option which doesnt turn on the hot water when set to the on position. there is also no heating control option at all on the app. any help would be appreciated. cheers guys.
-
Boiler keeps turning off when it has not reached temperature
The temperature is about 15C and I have set all the radiators and controller to 25C. The boiler started to heat and then a couple of minutes later stopped heating. Then later started heating again and then stopped. The radiators get very slightly warm but never warm enough to actually raise the temperature in the room. Any…
-
Energy consumption per room estimates
Hi, in the explanation of how Tado estimates the energy consumption per room it says that it assumes each room consumes the same amount if heating is active for the same amount of time. That seems reasonable, unless there are multiple radiators in a room. Does anyone know if Tado takes this into account, assuming each…
-
Heating partial load/ range rating
Hi Folks, Hope you can advise. Keen to reduce usage/cut bills. How do I find the range rating on Vaillant Eco Tec pro 28? Looking to see if it's auto or should be lowered? (To what?) I'm in a top foor/2nd floor 3 bed flat all on one floor, built around 2000 and I've 10 radiators. Gas does rads and hot water and electric…
-
TRV’s not being passed heat when requested
Hi all, I have now connected the zone controllers but now have a new issue. I have two wired smart thermostats that go to their own zone switches in the cupboard upstairs. They’re then connected to the boiler by electrical connection (Electric boiler) . The issue I have is that the boiler only gets called for heat when one…
-
Will it work?
Hi Looking to get a Tado system, we have an Ideal Esprit eco 30 that has a built in timer unit and a Sangamo twisty thermostat in the wall. A) Will the Tado system work with our set up and, If so, B) Will it be a pain to install? Thanks
-
Extension Kit as a Hot Water Programmer - Help!
Hello, I am having trouble with adding a wireless extension kit to control my hot water programmer. Quick summary of my existing setup: I have had a Tado setup in my house (a 4-year-old new build) for about 4 months. There 2 thermostats downstairs which connect to UFH. Upstairs there is another thermostat setup as a zone…
-
Is it possible to see room graphs via Tado for nearly 2 years ago?
My graphs only go back 12 months. Are they stored eg by Tado anywhere? Thanks
-
Signal Keeps Dropping - Internet Bridge light flashing
My tado system has been workng well since installation until recently - The internet bridge keeps falling off and goes "offline" It seems to drop on and off at certain times of the day, and then at other times works well I have located the bridge right at the centre of the house, reasonably near to the boiler and centre to…
-
tado V3 not support Mitsubishi air conditioners
:'( Just replaced two Mitsubishi air conditioners for my new home, when I setting up for the new machine, tado can rec the rc signal but the apps keep saying we couldn't identify your AC model Signal detected Could not identify AC AC model : 1) Mitsubishi SRK53MWKH1 2)Mitsubishi SRK25MHIP1 Any one can help? No any reply…
-
Boiler switches from Constant on to Automatic then does not respond to Tado
I have a Worcester Bosch Greenstar HE 35 connected to wireless Tado. I set the boiler to ‘Constant on’. Everything works fine. However, for some reason the boiler switches itself from Constant on to Automatic, then it does not respond to the Tado until manually switched back to Constant on. Can anyone help/advise how to…
-
Three zone central heating system
I have a three zone central heating system with a programmable thermostat on each floor controlling a 2 port motorized valve. Can I replace the thermostats with wired tado smart stats. I do not need smart HW control