Room Thermostat not working
Anyone have tips/suggestions on how to fix the following problem, or is it terminal? I have a tado room stat and it's not switching. At one point the heating was stuck on, now it's stuck off. The thermostat is online and I can make changes to the temp on the app and see them on the stat display. But I never hear the click…
-
Adaptor for Pintossi M26 Valves
Hi Folks, I am based in Australia, and have had trouble sourcing the adapter Pintossi M26 valves for the Smart Thermostat. Does anyone know where I can source them at reasonable cost. I have 16 radiators to connect! Thanks Polmac
-
Hot water schedule
Hey guys, Had my system installed and working fine for the last few weeks. Last night Sunday as the clocks went back tado failed to activate our hot water schedule but everything else worked Cold shower this morning so not very happy. Working again now but why didn't it activate
-
Balance AC
Is anyone else using Balance AC? It doesn't seem to be working in the UK, it hasn't shown any values for the last few days I've looked. I'm also not convinced it works the way it says it should, I've got 3 heat pump AC indoor units used for heating and there have been times when one is above the target temperature, one…
-
App not working
Anyone else not able to login to their Tado app today? Keeps hanging with the loading spinner going round and round…
-
Heating on when programmed to off
This morning the heating came on but tado was programmed to off and not due to come on till later . Any ideas? I only have one thermostat on one room
-
Can I take my central thermostat out of the equation?
Hello, I don’t have a great understanding of how heating systems work but I’ll try my best to explain the context and question. Before tado, we started with a new vallaint boiler and a salus central thermostat + boiler control. We started by installing tado SRVs on most radiators and they worked great, except that the…
-
Automation disabled after manual input
Hi, I have a scheme active, however when i change the temparature manually on the thermostat the scheme disables. Is there a way to reactivate this automaticly when the next time scheme starts?
-
Disconnected while away
Was away on holiday, checked the thermostat temperature only to find it had disconnected, made contact with Tado to find out remote pairing could not be done. Stopped the holiday, got home and paired devices in seconds, the frustrations behind this happening was the comments from Tado on possible cause one was to make sure…
-
Heaters dont on or off on app
I have tadi installed 6 months ago and everything working fine until last month. Since last month I can only turn off hesting from wireless receiver. Whatever the changes I do are showing up wireless temporature sensor but heaters are not actually changing the heat, not on or off. From app in rooms and devices all are…
-
New boiler and EU wireless receiver installed - any software changes required?
Hello all, I had some advice on there about replacing my boiler and making sure Tado was Open Therm compatible so it can modulate the boiler. The boiler has now been replaced, and an EU wireless receiver has been installed and added to the app in place of the old UK receiver. I did ask about this on chat but I'm not sure…
-
What set up do I need?
It's seems a few people has the same problem as me too much jargon. I need help selecting what kit I need chat service made 3 different responses. I don't want bridges everywhere just want to replace thermostats with smart ones to control dual zone downstairs heating and water upstairs heating only. Both thermostats are…
-
Replacing Giacomini TRV
Found an adapter in the kit but can't find anything that would keep the extension pin central. Anyone had this problem? Did find one post but with no answer.
-
Polypipe Wiring
Hello, I wonder if you can help me please. I have purchased the Tado wired starter pack and a few wired thermostats to replace my old Polypipe wired thermostats. I have a water based under floor heating system. The thermostats only have 2 wires (blue and brown). The Polypipe thermostats are battery powered. Am I correct…
-
Multi zone, rads and ufh design
Hi all, I have a few design questions: I have 8 rooms, 3 zone valves (+ hot water valve), due to constrains all zones need wireless temperature control. zone valve 1 = 4 rooms / 4 rads zone valve 2 = 3 rooms / 3 rads zone valve 3 = 1 room / 1 ufh As far as I can work out i need the following: z1 (+ hw) = Wireless Smart…
-
Thermostat no longer works
For 6 years my Tado system has worked without issues. It is a simple setup, just a bridge and 1 thermostat. No changes made in the setup, but suddenly the Thermostat no longer works. Symptoms are the following: - Thermostat doesn't show the temperature if you press the button at the front. - No connection via the app on…
-
Heating
I have smart thermostats on all my radiators however whenever I turn the living room radiator on, one bedroom radiator heats up even though that thermostat is turned off. I have tried the usual steps like re-calibrating and swapping thermostats but the problem remains. The bedroom thermostat shows as off but still heats up…
-
Energy iq
Installed Tado and a new smart meter on same day Tado energy is saying usage 781kwh Meter reading 61kwh Anybody else with same problem
-
Tado rad thermostats pop off
I have danfoss ra valves and when the thermostats are installed onto the adapter it can pop of the threads, read that these adaptors are not a perfect fit and there is a metal alternative. Anyone know where I can get these metal adaptors? In the meantime I have had to use thread tape on the threads to keep the thermostats…
-
Drayton Wiser
I have had Tado coming up to a month and although it is working fine, I can'tget over issue is lack of local scheduling in the event of cloud failure etc. I think this is because I previously had Hive. I know with Drayton Wiser you can configure it to set up a local network enabling you to set/amend schedules in the event…
-
Hive to Tado wiring terminal mapping
Hello, I'm attempting to replace my existing Hive setup (SLR2 + SLT3) with a Tado Wired Thermostat, but I'm confused by the instructions. Here is how my Hive dual-channel receiver is currently wired: Note that it says NL1234, and with two other wires going into the earth by the side. But the tado backplace looks like this:…
-
Who has SRV's only on part of the system and how is it working out?
Hello, when fitting SRV's to half of the radiators or less, which rooms did you choose, why and how have you set it up to operate? I ask as I thought that it would make sense in my house to just do upstairs for now and keep them off a lot of the time like an upstairs zone but someone I spoke to recently told me he has them…
-
GAS kWh used.
Guy's, I'm interested to know what your GAS usage has been like, I have just ordered a Weather Compensation KIT for my Baxi 836 Combi Boiler (atm I am using OpenTherm), and I'm interested to know if you think I can get more efficiency out of my boiler, I have attached my GAS usage by day since December 2022, and I would…
-
Hot water schedule not activating
Hey guys, Had my system installed and working fine for the last few weeks. Last night Sunday as the clocks went back tado failed to activate our hot water schedule but everything else worked Cold shower this morning so not very happy. Working again now but why didn't it activate
-
Battery Life - Smart thermostat
Hello all, I’m experiencing a very annoying issue with my smart thermostat. At the moment I have to replace the three triple AAA LR03 almost weekly as they die. The thermostat is less than 10 metres from the Hub and is free from any dust or debris. I was wondering if anyone has come across any similar issues and how they…
-
Wrong temperatures
Our bedroom TRV is set to 16C but the app shows 20C. I have a digital thermometer in the room and it’s showing 12.5C. Please help!
-
Smart Radiator Thermostat Not Powering
One of my smart radiator thermostats (which I bought back in December) is now not working, despite working perfectly during the last season. It does not power up, even with brand new batteries, and everything has been checked with support and they have suggested a replacement. The issue is that although this device is…
-
Tado SRV's suitable for humid shower room or bathroom?
Hello, are the Tado SRV's suitable for a small shower room which will get very humid and possibly dripping condensation forming on some surfaces but no direct splashes or water? Or a bathroom, used occasionally for baths, which gets a damp atmosphere but again, no direct splashes of water from the bath? Shower room, humid…
-
Hot water comes on if heating on. But doesn't work on it's own
Just installed a Tado wireless thermostat, internet bridge and wireless receiver. The hot water works ok when the heating is on. When i put hot water on seperately, it tries to start but eventually the boiler just trips out and i have to reset it. The boiler is a Worcester Bosch Greenstar ri. I am thinking the 3 way valve…
-
underfloor heating pump control
Hi. I have a wired room thermo controlling boiler via digital controls. I also have wet underfloor heating that comes on via a flow item sensor so that when heating turns on and the underfloor heating sensors detects heat, it switches on. I would like to control the UFH with tado. I believe I cannot use the relay on the…