Baxi duo-tec 40 he a . Tips for receiver
Not started the install yet. Just doing my research first. Got a baxi boiler, currently using a salus rt510 tx wireless thermostat. The RF receiver is integrated into the boiler . I'm assuming that will just unplug . Is it a simple swapping the wires out for the new tado receiver . Not looked at where the salus receiver…
-
In hoeverre is Opentherm modulerend
Hallo, Ik heb wat temperatuur sensoren op mijn aan- en afvoerleiding bij de CV ketel geplaatst om wat gegevens over temperaturen te registreren. Volgende stap is een Opentherm gateway tussen de thermostaat en de ketel; die staat klaar, maar moet nog aangesloten worden. Bijgaand een screenshot van de registraties. Als ik de…
-
Motor head stuck on motor base
I frequently find, when changing batteries, that the motor head is stuck in its base and so I end up removing head and base together, then needing to separate the two, then reassemble. When I fit the base to the valve or adaptor I crank it up by hand as tight a I can using anti-slip cloth. I really don't think I should…
-
TRVs - broken black pins
My experience with tado has been absolutely horrible, I did manage to make '6' TRVs work in my home. Not reliably - two of the really shoddy plastic connectors always act up. Yesterday, for instance, one of the TRVs that I WANTED to be at 16 degrees in one room, actually ended up being (once again) at 32 (!!!) degrees. But…
-
Hi all, a question regrding the wireless temperature sensor.
I have had the starter kit installed for almost a year now. However, I happened to attempt to show my wife how to increase the temperature for the heating to come on but when you press the arrows, it does not allow you to increase the temperature. in other words it does not move. any ideas please. I have tried resetting…
-
Ecotec Pro 28
Hi newb here looking for some info i am thinking about getting the Tado V3 wireless thermostat kit. What would i need to do with the already working thermostat on my downstairs wall does this need to be decommissioned and just left alone or do i have to put the new tado thermostat in its place ? I had a quick look at a…
-
Are there line or cad drawing of the tado TRV?
Would love to have some drawings of the dimensions and distances moved by the pin within the tado TRV so that I can use that information to make up an adapter for an old TRV valve… it’s got the correct screw thread to allow the mounting of the tado unit but once connected and the tado TRV has done it’s calibrations all…
-
Thermostat switched off but radioator is warm and keeps heating
Hi, My Thermostat switched off but radioator is warm and keeps heating.I followed all the steps below but the problem is still there.(VA1380582656) Please,help me,best,s Please remove the Smart Radiator Thermostat from your radiator and take out the batteries for a few minutes. Please re-insert the batteries into the Smart…
-
Latest update the outside local temperature is not showing in temp graph?
Hi, I have noted that the local exterior temperature is not showing anymore with the Temp & Humidity Graph. It looks like it is there but completely to right and condensed. i am using iOS on apple devices. Not sure if latest update of iOS or Tado is causing this. Anyone else having the same issue? Thanks, Max
-
One-off Notification
Hello, Sometimes I open the Tado app and see some room heating is on even though it was not scheduled to be. Is it possible to have a notification every time a thermostat/TRV is turned on or off?
-
Hot water and Heating are coming on together
Hi, I just installed my starter kit and I think that something is not right. When the heating comes on, the hot water light comes on at the same time so it appears that hot water is running at the same time and central heating. In the APP the hot water is not showing as being on. The hot water does not appear to be able to…
-
Ideal Boiler Logic C35 help
Dear all Looking to install Tado starter kit to this boiler. Already have a salut RF system in place. It already has no, com, L and N wired. Can I just replace the No and Com. Does it need L and N ? Thanks in advance
-
Dual zone and HW tank control with Tado
Hi all, My current setup: HW tank with WB Greenstar 8000 life system boiler. I have two wired ESI thermostats, one downstairs and one upstairs. I have a Levante LEVHC2P controller next to the hot water tank on the middle floor and the boiler is in the kitchen. 3 valves control upstairs heating, downstairs heating and hot…
-
No heating after power outage
Hi, I'm hoping someone can help me with our Tado V3+ starter kit that after working perfectly for 6 months has stopped working after we needed to turn the electricity off for about 30mins. The boiler is a combi boiler and the hot water is still working fine. The wireless receiver connected to the combi boiler has the power…
-
Which adaptor do I need for my trv valve?
Hi I am getting an E2 error after using one of the adaptors with my radiator valve. Which adaptor do I need to use for this valve?
-
Smart thermostat gone missing?.
Hi All smart stat is not now showing on app? Boiler is also firing when no call for heat? I have power cycled hub and thermostat and tried to pair but nothing changes Display on smart stat is active and if I hold for 3 seconds it shows the paired symbol i have changed nothing recently apart from combine 2 rads that were in…
-
Tado Vaillant combi modulate flow
Hi Folks Been asked a few times on here but I can't find a definitive answer. Can you get Tado to control the flow temp on a Vaillant combi? (Bought the wireless Tado starter kit then changed the wireless receiver to EU version to get flow control. Gas guy put it in a year ago on on/off mode. No point getting him back if…
-
Max flow temp not being reached
Hi I installed a tado to my green star 36cdi compact boiler a few weeks ago using the bus connection I have noticed my flow temp never goes above 55 degrees when I have it set at max on the boiler when I look at the pro app it says to adjust the max flow temp at the boiler which I have done so I can only assume the tado is…
-
Away Mode Use
Hi all, I’m just returning from a 10 day holiday. When we left, I manually set Tado to Away mode with all rooms set to frost protection only and water off - I have an extension kit fitted to the combo boiler. I had a look at the temps of the rooms a few days and was surprised to see the kitchen room trying to heat to 21c -…
-
My tado suddenly stoped working as it should be
Hello evryone, I'm the owner of tado since 6th of December 2023, everything was working fine and as it should be until 10th of January 2024, when I've come back home from work (night shift) and my heating wasn't on, despite setting up geofence in the app on my phone (geofence was working fine till that day), I had to…
-
Boiler not working after connecting wireless receiver
Hi, I have set tado up with the thermostat and trvs and internet bridge, all was working fine. So I thought I'd jump in and connect the wireless receiver. I followed all instructions, everything says it it's fine in the app, however now the boiler is not firing up. I have checked that the TRVs and thermostat zone…
-
Vaillant Heating Partial Load
Hi - I recently installed a wireless Tado on a Vaillant ecoTEC plus 837 which all works together beautifully in our 120m2 apartment. While checking settings, I noticed that the Vaillant Heating Partial Load has been set to 15kW rather than the default auto setting. Before I change this to auto, is there any potential…
-
What to if wifi goes down?
Hi, We have just installed Tado Wireless Receiver. We wanted to test what happens if our wifi goes down and we need to turn on/off the water or heating. We were sent instructions by Tado which were supposed to tell us how to do this but they don't work for us. Has any one succeeded in turning on/off the heating or water if…
-
Help! My Boiler is constantly firing!!
I’ve recently swapped out my Danfoss thermostat with a TADO smart wired one and also swapped out the TRVs for smart ones with sensors. However now my boiler is constantly firing. There is a radiator in the hall that does not have a TRV and it is constantly red hot. I installed the product as per the app and it works great,…
-
Boiler not working
Hi, Unfortunately my boiler is not working Glow worm betacom 3. Does anyone know if this wiring is correct. Any help much appreciated
-
Tado to replace Honeywell
I have an oil fired system, with a hot water tank. Currently it uses a Honeywell HCW80 wireless thermostat. There is a Honeywell R6660D relay/receiver unit in the airing cupboard and a Honeywell ST9400c 7 day, 2 channel programmer next to the boiler. I’d like to replace this lot with the V3+ wireless starter kit. I presume…
-
Help with repeated loss of CH/HW - Tado Thermostat and UK Wireless Receiver - Device Error
For two mornings in succession now, no CH/HW. The iOS app shows crosses in the status boxes for temp and HW status. On morning 1, the app showed wireless receiver offline. Various power cycles and re-pair attempts got it working. On morning 2, the app reported no connectivity issues, but it was not working. Several…
-
Combi Boiler DHW Question
Hi A quick question for all you technical people out there is this normal behaviour for a Combi boiler? When DHW is requested the CH flow temp is increasing as shown in the graph below or is my diverter valve passing? Thanks in advance for any response Craig
-
TRV causing radiator vibration
Hello, I have been having huge problems with the TRV on one of my radiators. It is installed using a M28x1.5 adapter which I had to cut the pin down a little to shorten as it was too proud. I have two radiators using this adapter. One is fine but the other one sporadically causes a loud vibration that sounds like drilling,…
-
Radiator valve periodically goes offline
For a couple of months now one of my Tado radiator thermostat valves keeps going off line for anything between 30 minutes and 4 hours. Does anyone have any idea(s) as to what my problem might be. Please note I use rechargeable batteries and I have already tried recharging them to solve the problem. Thanks in advance.